SSi Manual 4559 Page 1 of 26 3-Gas Analyzer PGA3500
Revision Level - D
Operations Manual
PGA 3500
Portable 3-Gas IR Analyzer
Please read, understand, and follow these instructions before operating this equipment.
Super Systems, Inc. is not responsible for damages incurred due to a failure to comply with these
instructions. If at any time there are questions regarding the proper use of this analyzer, please
contact us at (800) 666-4330 for assistance.
7205 Edington Drive
Cincinnati, OH 45249
513-772-0060 800-666-4330
Fax: 513-772-9466
www.supersystems.com
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1 - PGA 3500

SSi Manual 4559 Page 1 of 26 3-Gas Analyzer PGA3500 Revision Level - D Operations Manual PGA 3500 Portable 3-Gas IR Analyzer Please read, unde

Seite 2

SSi Manual 4559 Page 10 of 26 3-Gas Analyzer PGA3500 Revision Level - D IR Status Display – Menu Page 1 The IR status display shows the current rea

Seite 3

SSi Manual 4559 Page 11 of 26 3-Gas Analyzer PGA3500 Revision Level - D information has not been entered correctly the resulting carbon calculation

Seite 4

SSi Manual 4559 Page 12 of 26 3-Gas Analyzer PGA3500 Revision Level - D large changes in CO Factor or Process Factor should be verified by shim stoc

Seite 5 - Specifications

SSi Manual 4559 Page 13 of 26 3-Gas Analyzer PGA3500 Revision Level - D off, the instrument still operates fully, but the display is more difficult

Seite 6

SSi Manual 4559 Page 14 of 26 3-Gas Analyzer PGA3500 Revision Level - D desired language and then press the Enter key. The selected language will b

Seite 7 - Battery

SSi Manual 4559 Page 15 of 26 3-Gas Analyzer PGA3500 Revision Level - D Revision Display – Menu Page 11 This page shows the firmware revision levels

Seite 8 - Menu List

SSi Manual 4559 Page 16 of 26 3-Gas Analyzer PGA3500 Revision Level - D Pressing the circular arrow button will display the following five variables

Seite 9 - Note about Menu Numbers

SSi Manual 4559 Page 17 of 26 3-Gas Analyzer PGA3500 Revision Level - D Jones, then to select B. Smith, the user can enter a 2 while the “Operator”

Seite 10 - Calculated

SSi Manual 4559 Page 18 of 26 3-Gas Analyzer PGA3500 Revision Level - D with an instrument that can provide real-time temperature data. The purpose

Seite 11 - Revision Level - D

SSi Manual 4559 Page 19 of 26 3-Gas Analyzer PGA3500 Revision Level - D Minimum mV – 1200 Maximum Adjustment – 1 Maximum COF/PF – 250 Minimum COF/PF

Seite 12 - Pump Control - Menu Page 4

SSi Manual 4559 Page 2 of 26 3-Gas Analyzer PGA3500 Revision Level - D TTaabbllee ooff CCoonntteennttss Table of Contents ...

Seite 13 - Help Page - Menu Page 6

SSi Manual 4559 Page 20 of 26 3-Gas Analyzer PGA3500 Revision Level - D Zero Calibration – Menu Page 18 This page is used to zero the IR cells. It

Seite 14 - Battery Status – Menu Page 9

SSi Manual 4559 Page 21 of 26 3-Gas Analyzer PGA3500 Revision Level - D outside to be sure that the process gas does not influence the ambient air.

Seite 15

SSi Manual 4559 Page 22 of 26 3-Gas Analyzer PGA3500 Revision Level - D The Furn TC Inst Type is the make and model of the instrument that will be s

Seite 16 - Session - Menu Page 14

SSi Manual 4559 Page 23 of 26 3-Gas Analyzer PGA3500 Revision Level - D changed after determining that additional adjustments are required based on

Seite 17 - Pump Control – Menu Page 4

SSi Manual 4559 Page 24 of 26 3-Gas Analyzer PGA3500 Revision Level - D default setting for Level 1 is 1, and the default setting for Level 2 is 2.

Seite 18 - Minimum Temp – 1500

SSi Manual 4559 Page 25 of 26 3-Gas Analyzer PGA3500 Revision Level - D PPGGAA33550000 SSppaarree PPaarrttss • Factory Calibration Part N

Seite 19 - Port Setup - Menu Page 17

SSi Manual 4559 Page 26 of 26 3-Gas Analyzer PGA3500 Revision Level - D RReevviissiioonn HHiissttoorryy Rev. Description Date MCO # - Initial R

Seite 20 - Zero Gas

SSi Manual 4559 Page 3 of 26 3-Gas Analyzer PGA3500 Revision Level - D WWAARRNNIINNGGSS Shipping the instrument back to Super Systems When retu

Seite 21

SSi Manual 4559 Page 4 of 26 3-Gas Analyzer PGA3500 Revision Level - D TTyyppiiccaall DDiiaaggnnoossttiicc UUsseess ooff tthhee PPGGAA33550000

Seite 22

SSi Manual 4559 Page 5 of 26 3-Gas Analyzer PGA3500 Revision Level - D PPGGAA 33550000 OOppeerraattiinngg IInnssttrruuccttiioonnss Introductio

Seite 23 - Span Gas

SSi Manual 4559 Page 6 of 26 3-Gas Analyzer PGA3500 Revision Level - D Basic Operating Description The Model PGA 3500 has been designed for the sim

Seite 24 - Set IP Address- Menu Page 26

SSi Manual 4559 Page 7 of 26 3-Gas Analyzer PGA3500 Revision Level - D On a furnace, the ideal port would be found on SSi’s Sample Port (Part Number

Seite 25

SSi Manual 4559 Page 8 of 26 3-Gas Analyzer PGA3500 Revision Level - D It is possible to view the condition of the battery by accessing Menu page #9

Seite 26

SSi Manual 4559 Page 9 of 26 3-Gas Analyzer PGA3500 Revision Level - D (default = 1). Pages 22 – 26 are Configuration screens requiring a Level 2 p